Version 1.2
11.01.2006
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: * Input: Output: 25 0 C dBm
Filter specification
TFS 70AV
1/5
48 || -34 pF 49 || -35 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 70AV is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 70MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss (reference level) Nominal frequency Passband Pass band ripple (p-p) Bandwidth ** 0,5 40 dB dB arel 9,125 MHz 20,0 MHz BW PB Ae fN
typ. value
13,5 dB
tolerance / limit
max. 14,5 70,0 fN 5,0 0,5 dB MHz MHz dB
0,3
dB
max.
10,8 16
MHz MHz
min. max.
10,0 18,25
MHz MHz
Relative attenuation fN 20,0 MHz ... fN 9,125 MHz ... fN + fN + Group delay ripple within PB (p-p) Phase linearity within PB Operating temperature range Storage temperature range
50 44 45 5,5
dB dB ns
min. min. max. max.
40 40 90 11,5
dB dB ns p-p
OTR TCf *** -73 ppm/K
- 40 C ... + 85C - 40 C ... + 85C
Temperature coefficient of frequency
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) at 25C ***) fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70av.doc
Version 1.2
11.01.2006
VI TELEFILTER
Filter characteristic
0
Filter specification
TFS 70AV
2/5
0
1.44
-6
-0.1
1.38
-12
-0.2
1.32
-18
-0.3
1.26
magnitude in dB
magnitude in dB
-24
-0.4
1.2
-30
-0.5
1.14
-36
-0.6
1.08
-42
-0.7
1.02
-48
-0.8
0.96
-54
-0.9
0.9
-60 52.2
55.8
59.4
63
66.6
70.2 73.8 frequency in MHz
77.4
81
84.6
88.2
-1 63.2
64.6
66
67.4
68.8 70.2 71.6 frequency in MHz
73
74.4
75.8
0.84 77.2
Construction and pin connection
(All dimensions in mm)
13,6Max.
TFS 70AV T51
1
1,5 2,54 0,15
2,54 0,15
1234 12 11 10 9 8 7
0,8 0,1
2,0Max.
Date code
1 2 3 4 5 6 7 8 9 10 11 12
Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return
6,8Max.
5 6
Date code: T U V ...
Year + week 2005 2006 2007
50 Ohm Test circuit
L1
11 12
5
L2
SAW
6
C2
C1
1, 2, 3, 4, 7, 8, 9, 10
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
delay in s
Filename: tfs 70av.doc
Version 1.2
11.01.2006
VI TELEFILTER
Stability characteristics
Filter specification
TFS 70AV
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 1700 min. 300 mm min. 500 mm min. 300 mm
Pull Off Direction
Tape (all dimensions in mm) W : 24,00 +0,30/-0,10 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,10 F : 11,50 0,10 G(min) : 0,60 P2 : 2,00 0,1 P1 : 12,00 0,1 D1(min) : 1,50 Ao : 7,10 0,10 Bo : 13,90 0,10 Ct : 21,5 0,1
P1 t Do PIN Marker Po P2
E G Ct Bo F
Ko
Date Code
Typ
D1
Ao
W2
Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2
C A N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
G
W
Filename: tfs 70av.doc
Version 1.2
11.01.2006
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 70AV
4/5
Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature
Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds
Chip-mount air reflow profile Temperature / C
max. 260C
217C
max. 300 s
10 ... 30 s 30 ... 150 s
Time / s
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70av.doc
Version 1.2
11.01.2006
VI TELEFILTER
History
Version 1.0 1.1 Reason of changes
Filter specification
TFS 70AV
5/5
Name Chilla Chilla
Date 09.11.2005 16.12.2005
- Generation of development specification - Created filter specification - Added termination impedances - Delated 1dB bandwidth - Added filter characteristics - Added test circuit - changed temperature coefficient of frequency
1.2
Chilla
16101.2006
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS70AV

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X